I/P Converter

Prominent & Leading Manufacturer from Greater Noida, we offer ip converter onlne, explosion proof i/p transducer, t550x miniature i/p, e/p transducer, t595xp explosion proof i/p transducer, electropneumatic transducer (e/p) and t590x manifold mount i/p transducer.

IP Converter Onlne

₹ 20,000 /Piece Get Latest Price

MaterialAluminium Diecasting
Air ConsumptionBelow 2 LPM (sup = 0.14 MPa)
Flow Capacity70 LPM (sup = 0.14 MPa)
Explosion Temperature-40 to 60 Deg C (T5) / -40 to 40 Deg C (T6)
Air Connection(N)PT 1/4
ConduitG 1.2 (PF 1/2)
Ingress ProtectionType 4X, IP66
ImpedanceMax. 313 Omega @ 20 mA DC
Sensitivity+/-0.2% F.S.
Weight3 kg (6.61 lb)
Operating Temperature-40 to 85 Deg C (-22 to 185 Deg F)
Repeatability+/-0.3% F.S.
Linearity+/-0.5% F.S.
Input Signal4 to 20 mA DC
Hysteresis+/-0.5% F.S.

Design Features:

  • Flameproof Housing (YT-940) for Zone 1 installation.
  • High Accuracy and Sensitivity with pressure sensor.
  • Analogue PID control. High resolution proportional control
  • No effect from mounting orientation.

 

Specifications:

Output Signal Standard 0.02 to 0.1 MPa (0.2 to 1.0 bar)
Multirange 0 to 0.12 MPa (0 to 1.2 bar)
0.04 to 0.2 MPa (0.4 to 2.0 bar)
0 to 0.23 MPa (0 to 2.3 bar)
Supply Pressure Standard 0.13 to 0.16 MPa (1.3 to 1.6 bar)
Minimum 0.2 bar greater than the maximum calibrated output pressure
Maximum 0.24 MPa (2.4 bar)
Explosion Protection Type ATEX, IECEx Ex ia IIC T5/T6 Gb,Ex ia IIIC T100°C/T85°C Db FM Class I Division 1 Groups A,B,C,D Class II, III Division 1 Groups E,F,G Class I Zone 1 AEx d IIC T6 Ta=-40°C to + 75°C,T5 Ta=-40°C to + 85°C,Type 4X, IP66Zone 21 AEx tb IIIC T85°C Ta=- 40°C to +75°C, T100°C Ta=-40°C to +85°C, Type 4X, IP66 Kcs Ex d IIC T5/T6

Get The Best Price Of IP Converter Onlne For Rs.20000/-

Explosion Proof I/P Transducer

₹ 12,000 /Piece Get Latest Price

Port Size Pneumatic1/4" NPT
Port Size Electric1/2" NPT M20 x 1.5 (ATEX)
Air Consumption3.0 scfh (1.5 Nl/min) at mid range
Inputs4-20 mA
Weight1.8 lbs (0.82 kg)
Supply Pressure100 psig (7.0 BAR) maximum
Loop Load9.5 VDC @ 20 mA (500 Ohms resistance)
Deadband0.02% of span
MountingDirect wall, panel, or 2" pipe (optional)

To cater to the demands of our customer’s consideration, we are extremely engaged in manufacturing and supplying Explosion Proof I/P Transducer. The offered product is developed with the help of best quality material and sophisticated technology, in accordance with set industrial standards. As well, this product is inspected by our in-house quality experts on various parameters in order to guarantee that we are offering only defect free range.

Features:

  • Simple usage
  • Long service life
  • Efficient performance

Specifications:
Output3-15 psig 0.20-1.00 BAR
3-27 psig 0.20-1.80 BAR
6-30 psig 0.40-2.00 BAR
Air Consumption3.0 scfh (0.11 m3/hr) at mid range
Supply Pressure100 psig (7.0 BAR) maximum
Note: Supply pressure must be a minimum of 5 psig above maximum output
Flow Capacity4.5 SCFM (7.6 m 3/hr) at 25 psig
(1.7 BAR) supply
12 SCFM (20.0m 3/hr) at 100 psig
(7.0 BAR) supply
Temperature LimitOperating: -40° to + 160°F (-40° to + 71°C)
Storage: -40° to + 200°F (-40° to + 93°C)

T550X Miniature I/P, E/P Transducer

  • Foil Print

₹ 8,000 /Piece Get Latest Price

Size38.1x55.4x130 mm
Weight2.1 lbs. (0.94 kg)
Port Sizes1/4 NPT(Pneumatic) 1/2 NPT(Electric)
Temperature Range-20Deg F to +140Deg F (-30 Deg C to 60 Deg C)
MediaOil free, clean dry air filtered to 40 micron
Inputs4-20 mA, 0-5 VDC,0-10 VDC, 1-9 VDC

Specifications:

  • The ControlAir Type-925 Multifunction Manifold provides a common supply port and individual shutoff valves for sets of 3, 5, 10 or 15 units.

Technical Specifications:
Low Output Range (Up to 30 psig)High Output Range (Up to 120 psig)
Min./Max. Supply PressureMinimum - 3 psig (0.2 BAR)
above maximum output
Maximum - 100 psig (7 BAR)
Minimum - 5 psig (2 BAR)
above maximum output
Maximum - 150 psig (10 BAR)
Supply Pressure Sensitivity<± 0.1% of span per 1.0 psig
(<± 0.15% of span per 0.1 BAR)
<± .04% of span per 1.0 psig (0.07 BAR)
Terminal Based Linearity<± 0.75% of span<± 1.5% of span typical, ± 2.0% max.
Repeatability< 0.5% of span< 0.5% of span
Hysteresis< 1.0% of span< 0.5% of span
Response TimeDependent on pressure range - typically less than 0.25 sec for 3-15 psig units
Flow Rate4.5 scfm (7.6 m 3/hr ANR) at
25 psig (175 kPa) supply
12.0 scfm (20.0 m 3/hr ANR) at
100 psig (700 kPa) supply
20.0 scfm (34.0 m 3/hr) at
150 psig (1050 kPa) supply
Relief Capacity2 scfm (3.4 m 3/hr) at
5 psig (35 kPa) above
20 psig (140 kPa) setpoint
7 scfm (3.4 m3/hr)
at 10 psig (35 kPa) above
20 psig (140 kPa) setpoint
Maximum Air Consumption.05 scfm (.07 m 3/hr) midrange typical.07 scfm (.14 m3/hr) midrange typical
MediaOil free, clean dry air filtered to 40 micron
Temp. Range (Operating)-20°F to +140°F (-30°C to 60°C)
Port Sizes1/4 NPT(Pneumatic)
1/2 NPT(Electric)
1/4 NPT(Pneumatic)
1/2 NPT(Electric)
Weight2.1 lbs. (0.94 kg)2.1 lbs. (0.94 kg)

T595XP Explosion Proof I/P Transducer

₹ 15,000 /Piece Get Latest Price

Product Brochure
Height131.0 mm
Terminal Based Linearity+/-0.5% of span
RepeatabilityLess than 0.3% of span
Supply Pressure Max PSIG42 (2.8) (BAR)
Port Size Peumatic1/4 NPT
Port Size Electric1/2 NPT
Flow Capacity2.4 (72) SCFM (Nl/min)
Diameter73.7 mm

Converts a 4–20mA electrical current signal to a proportionally linear pneumatic output utilizing open loop control to provide a high level of accuracy and repeatability. Available with an integral volume booster or as a low-flow signal converter.

  • Compact design
  • Worldwide safety approvals
  • Vibration and position insensitive
  • Low power consumption

 

Specifications:

Input SignalOutput Range PSI (BAR)Model#
4-20 mA3-15 (0.2-1)595-AC
4-20 mA3-27 (0.2-1.8)595-AD
4-20 mA6-30 (0.4-2)595-AC

Electropneumatic Transducer (E/P)

₹ 8,498 /Piece Get Latest Price

Product Brochure
Size2.18 x 2.18 x 4.24 Inch
Response TimeDependent on pressure range - typically less than 0.25 sec for 3-15 psig units
Port Size Electric1/2 NPT
RepeatabilityLess than 0.5% of span
Flow Capacity12.0 (360) SCFM (Nl/min)
HysteresisLess than 1.0% of span Less than 0.5% of span
Weight2.1 lbs. (0.94 kg)
Terminal Based Linearity+/-0.75 % of span
Port Size Peumatic1/4 NPT, 1/4 BSP
Supply Pressure Max100 (7) PSIG (BAR)

The ControlAir Type-500X converts a current or voltage input signal to a linearly proportional pneumatic output pressure. This versatile instrument is designed for control applications that require a high degree of reliability and repeatability at an economical cost. The Type-500X is available in two different versions.The lower range model is designed for standard process control applications which typically utilize a 3 to 15 psig output.

Specifications:


Low Output Range (Up to 30 psig)High Output Range (Up to 120 psig)
Min./Max. Supply PressureMinimum - 3 psig (0.2 BAR)
above maximum output
Maximum - 100 psig (7 BAR)
Minimum - 5 psig (2 BAR)
above maximum output
Maximum - 150 psig (10 BAR)
Supply Pressure Sensitivity<± 0.1% of span per 1.0 psig
(<± 0.15% of span per 0.1 BAR)
<± .04% of span per 1.0 psig (0.07 BAR)
Terminal Based Linearity<± 0.75% of span<± 1.5% of span typical, ± 2.0% max.
Repeatability< 0.5% of span< 0.5% of span
Hysteresis< 1.0% of span< 0.5% of span
Response TimeDependent on pressure range - typically less than 0.25 sec for 3-15 psig units
Flow Rate4.5 scfm (7.6 m3/hr ANR) at
25 psig (175 kPa) supply
12.0 scfm (20.0 m3/hr ANR) at
100 psig (700 kPa) supply
20.0 scfm (34.0 m 3/hr) at
150 psig (1050 kPa) supply
Relief Capacity2 scfm (3.4 m 3/hr) at
5 psig (35 kPa) above
20 psig (140 kPa) setpoint
7 scfm (3.4 m 3/hr)
at 10 psig (35 kPa) above
20 psig (140 kPa) setpoint
Maximum Air Consumption.05 scfm (.07 m 3/hr) midrange typical.07 scfm (.14 m 3/hr) midrange typical
MediaOil free, clean dry air filtered to 40 micron
Temp. Range (Operating)-20°F to +140°F (-30°C to 60°C)
Port Sizes1/4 NPT(Pneumatic)
1/2 NPT(Electric)
1/4 NPT(Pneumatic)
1/2 NPT(Electric)
Weight2.1 lbs. (0.94 kg)2.1 lbs. (0.94 kg)

T590X Manifold Mount I/P Transducer

₹ 18,000 /Piece Get Latest Price

Voltage220 V
Usage/ApplicationIndustrial
Size3.3x1.4x2.0 Inch
Connection1/8" NPT (P)
Terminal Based Linearity+/-0.5% of span
Input Signal4-20 mA

I/P transducer uses open loop control and a low mass magnet to produce accurate pressure control at an economical cost. Position insensitive and impervious to RFI/EMI interference.

  • Vibration and position insensitive
  • Din rail and manifold mounting
  • Manifold or 1/8" NPT porting available
  • Wide operating temperature limits
  • Worldwide safety approvals

 

Specifications:

Input SignalOutput Range PSI (BAR)ConnectionModel#
4-20 mA3-15 (0.2-1)Manifold590-ACM
4-20 mA3-27 (0.2-1.8)Manifold590-ADM
4-20 mA6-30 (0.4-2)Manifold590-AEM
4-20 mA3-15 (0.2-1)1/8" NPT590-ACP
4-20 mA3-27 (0.2-1.8)1/8" NPT590-ADP
4-20 mA6-30 (0.4-2)1/8" NPT590-AEP

    P200 Pneumatic to Current PI Transducers

    ₹ 20,000 /Piece Get Latest Price

    Voltage220 V
    Usage/ApplicationIndustrial
    Size3.5x3.125 Inch
    Response Time0 m Sec to 99% of step change
    Outputs2 wire 4-20 mA and 10-50 mA with over-current limit
    Loads700 Omega (24 VDC)
    Country of OriginMade in India

    ControlAir's Dahl P200 P/I transducer represents outstanding value in pneumatic to current technology.

    Specifications:

    Inputs3-15 psig (0.2-1 BAR), 3-27 psig (0.2-1.8 BAR),6-30 psig (0.4-2 BAR) or customized up to 0-30 psig (0-2 BAR)
    Accuracy± 0.15% of span; ±0.10% of span typical.Includes combined effects of linearity,hysteresis and repeatability errors
    Temp. StabilitySpan and zero: ± 0.007% of span per ??F maximum deviation from 77 ??F calibration

    X

    Contact Us

    Abhishek Sharma (CEO)
    Millennium Instruments Limited
    F-12, Site B, Upsidc Industrial Area
    Greater Noida - 201306, Gautam Buddha Nagar, Uttar Pradesh, India

    Get Directions
    Send Email
    Share:
    Thank youYour Enquiry has been sent successfully.