Manufacturer of a wide range of products which include ytc smart positioner, smart valve positioner and smart positioner.
₹ 45000 / Piece Get Latest Price
| Material | Aluminium Diecasting |
| Input Signal | 4 to 20 mA DC |
| Supply Pressure | 0.14 to 0.7 MPa (1.4 to 7 bar) |
| Stroke Linear Type | 10 to 150 mm |
| Stroke Rotary Type | 0 to 90 Deg |
| Impedance | Max. 500 Omega @ 20 mA DC |
| Air Connection | PT(NPT,G)1/4 |
| Gauge Connection | PT(NPT)1/8 |
| Conduit | G(PF,NPT)1/2,M20 |
| Linearity | +/-0.5% FS |
| Hysteresis | +/-0.5% FS |
| Sensitivity | +/-0.2% FS |
| Repeatability | +/-0.3% FS |
| Output Characteristics | Linear, EQ%, Quick Open user set (18 Point) |
| Ingress Protection | IP66 |
| Communication | HART (ver.5) |
| Weight | 1.5 kg (3.3 lb) |
| Mechanical Type | AC 125 V, 3 A DC 30 V, 2 A |
| Proximity Type | DC 8.2 V 8.2 mA |
Specifications:
| Operating Temp. | Standard Type | -30 to 80 °C (-22 to 176 °F) |
| LCD | -30 to 85 °C (-22 to 185 °F) | |
| Explosion Temp. | -40 to 60 °C (T5) -40 to 40 °C (T6) | |
| Air Consumption | Fail Freeze | 0.01 LPM (sup = 0.14 MPa) |
| Fail Safe | 6 LPM (sup = 0.14 MPa) | |
| Flow Capacity | Fail Freeze | 60 LPM (sup = 0.14 MPa) |
| Fail Safe | 40 LPM (sup = 0.14 MPa) | |
| Explosion Protection Type | ATEX, IECEx Ex ia IIC T5/T6 Gb,Ex iaD IIC T85°C/T100°C IP6X | |
| NEPSI Ex ia IIC T5/T6 | ||
| Kcs Ex ia IIC T5/T6, EX iaD IIIC T100°C/T85°C | ||
₹ 40000 / Piece Get Latest Price
| Material | Aluminium Diecasting |
| Input Signal | 4 to 20 mA DC |
| Supply Pressure | 0.14 to 0.7 MPa (1.4 to 7 bar) |
| Stroke Linear Type | 10 to 150 mm |
| Stroke Rotary Type | 0 to 90 Deg |
| Impedance | Max. 500 Omega @ 20 mA DC |
| Air Connection | PT(NPT,G)1/4 |
| Gauge Connection | PT(NPT)1/8 |
| Conduit | G(PF,NPT)1/2, M20 |
| Linearity | +/-0.5% FS |
| Hysteresis | +/-0.5% F.S. |
| Sensitivity | +/-0.2% F.S. |
| Repeatability | +/-0.3% F.S. |
| Air Consumption | Below 2 LPM (sup = O.14 MPa) |
| Flow Capacity | 70 LPM (sup = O.14 MPa) |
| Output Characteristics | Linear, EQ%, Quick Open user set (18 Point) |
| Ingress Protection | IP66 |
| Communication | HART (ver.7) |
| Weight | 2 kg (4.4 lb) |
| Ambient Temp. | Standard Type | -30 degC-85 degC (-22-185 degF) |
| Low Type | -40 degC-85 degC (-40-185 degF) | |
| Explosion Temp. | -40 degC-40 degC (T6)/-40-60 degC (T6) | |
| LCD Operating Temp. | -30 degC-85 degC (-22-185 degF) |
₹ 45000 / Piece Get Latest Price
| Material | Aluminium Diecasting |
| Input Signal | 4 to 20 mA DC |
| Supply Pressure | 0.14 to 0.7 MPa (1.4 to 7 bar) |
| Stroke Linear Type | 10 to 150 mm |
| Stroke Rotary Type | 0 to 90 Deg |
| Impedance | Max. 450 Omega @ 20 mA DC |
| Air Connection | PT(NPT,G)1/4 |
| Gauge Connection | PT(NPT)1/8 |
| Conduit | G(PF,NPT)1/2, M20 |
| Linearity | +/-0.5% FS |
| Hysteresis | +/-0.5% FS |
| Sensitivity | +/-0.2% FS |
| Repeatability | +/-0.3% FS |
| Air Consumption | Below 2 LPM (sup = O.14 MPa) |
| Flow Capacity | 70 LPM (sup = O.14 MPa) |
| Output Characteristics | Linear, EQ%, Quick Open user set (18 Point) |
| Ingress Protection | IP66 |
| Communication | HART (ver.7) |
| Weight | 3.4 kg (7.5 lb) |
| Opeating Temp. | Standard Type | -30 degC-85 degC (-22-185 degF) |
| Low Type | -40 degC-85 degC (-40-185 degF) | |
| Explosion Temp. | -40 degC-40 degC (T6)/-40-60 degC (T6) | |
| LCD Operating Temp. | -30 degC-85 degC (-22-185 degF) |
₹ 40000 / Piece Get Latest Price
| Material | Aluminium Diecasting |
| Input Signal | 4 to 20 mA DC |
| Supply Pressure | 0.14 to 0.7 MPa (1.4 to 7 bar) |
| Stroke Linear Type | 5 to 35 mm |
| Stroke Rotary Type | 0 to 90 Deg |
| Impedancee | Max. 450 Omega @ 20 mA DC |
| Air Connection | PT(NPT)1/4 |
| Gauge Connection | PT(NPT)1/8 |
| Conduit | G1/2(PF1/2) |
| Linearity | +/-0.5% FS |
| Hysteresis | +/-0.5% FS |
| Sensitivity | +/-0.2% FS |
| Repeatability | +/-0.3% FS |
| Output Characteristics | Linear, EQ%, Quick Open user set (18 Point) |
| Ingress Protection | IP66 |
| Explosion Protection Type | KCs Ex ia IIC T5 |
| Communication | HART (ver.5) |
| Weight | 0.82 kg (1.8 lb) |
Specifications:
| Operating Temp. | Standard Type | -30 to 80 °C (-22 to 176 °F) |
| LCD | -30 to 85 °C (-22 to 185 °F) | |
| Explosion Temp. | -40 to 60 °C (T5) -40 to 40 °C (T6) | |
| Air Consumption | Fail Freeze | 0.01 LPM (sup = 0.14 MPa) |
| Fail Safe | 6 LPM (sup = 0.14 MPa) | |
| Flow Capacity | Fail Freeze | 9 LPM (sup = 0.14 MPa) |
| Fail Safe | 40 LPM (sup = 0.14 MPa) |
₹ 60000 / Piece Get Latest Price
| Material | Aluminium Diecasting |
| Input Signal | 4 to 20 mA DC |
| Supply Pressure | 0.14 to 0.7 MPa (1.4 to 7 bar) |
| Stroke Linear Type | 10 to 150 mm |
| Stroke Rotary Type | 0 to 90 Deg |
| Impedance | Max. 500 Omega @ 20 mA DC |
| Air Connection | PT(NPT,G)1/4 |
| Gauge Connection | PT(NPT)1/8 |
| Conduit | G(PF,NPT)1/2, M20 |
| Linearity | +/-0.5% F.S. |
| Hysteresis | +/-0.5% F.S. |
| Sensitivity | +/-0.2% F.S. |
| Repeatability | +/-0.3% F.S. |
| Air Consumption | Below 2 LPM (sup = O.14 MPa) |
| Flow Capacity | 70 LPM (sup = O.14 MPa) |
| Output Characteristics | Linear, EQ%, Quick Open user set (18 Point) |
| Ingress Protection | IP66 |
| Weight | 2 kg (4.4 lb) |
Specifications:
| Standard Type | -30 to 85 °C (-22 to 185 °F) |
| Low Temp.Type | -40 to 85 °C (-40 to 185 °F) |
| LCD | -30 to 85 °C (-22 to 185 °F) |
| Explosion Temp. | -40 to 60 °C (T5) -40 to 40 °C (T6) |
| Remote Sensor | -40 to 120 °C (-40 to 248 °F) |
₹ 40000 / Piece Get Latest Price
| Input Signal | 4 to 20 mA DC |
| Supply Pressure | 0.14 to 0.7 MPa (1.4 to 7 bar) |
| Stroke Linear Type | 10 to 150 mm |
| Stroke Rotary Type | 0 to 90 Deg |
| Impedance | Max. 500 Omega @ 20 mA DC |
| Air Connection | PT(NPT,G)1/4 |
| Gauge Connection | PT(NPT)1/8 |
| Conduit | G(PF,NPT)1/2, M20 |
| Linearity | +/-0.5% FS |
| Hysteresis | +/-0.5% FS |
| Sensitivity | +/-0.2% FS |
| Repeatability | +/-0.3% FS |
| Air Consumption | Below 2 LPM (sup = O.14 MPa) |
| Flow Capacity | 70 LPM (sup = O.14 MPa) |
| Output Characteristics | Linear, EQ%, Quick Open user set (18 Point) |
| Material | Aluminium Diecasting |
| Ingress Protection | IP66 |
| Weight | 2 kg (4.4 lb) |
Specifications:
| Standard Type | -30 to 85 °C (-22 to 185 °F) |
| Low Temp.Type | -40 to 85 °C (-40 to 185 °F) |
| LCD | -30 to 85 °C (-22 to 185 °F) |
| Explosion Temp. | -40 to 60 °C (T5) -40 to 40 °C (T6) |
₹ 40000 / Piece Get Latest Price
| Input Signal | 4-20 mA DC |
| Supply Pressure | 0.14-0.7 Mpa (1.4-7 bar) |
| Stroke | 5-50 mm |
| Impedance | Max 550 Omega @ 20 mA DC |
| Air Connection | PT(NPT)1/4 |
| Gauge Connection | PT (NPT)1/8 |
| Conduit | PF 1/2 (G1/2) |
| Ambient Temperature | -30 Deg C-80 Deg C |
| Linearity | +/-0.5% FS |
| Hysteresis | +/-0.5% FS |
| Sensitivity | +/-0.2% FS |
| Repeatability | +/-0.3% FS |
| Air Consumption | 0.01LPM (sup=0.14 Mpa) |
| Flow Capacity | 9LPM (sup=0.14 Mpa) |
| Output Characteristics | Linear, EQ%, Quick Open User set (16 point) |
| Material | Aluminum Diecasting |
| Enclosure | IP66 |
| Explosion Proof Type | Ex ia IIC T5/T6 |
| Weight | 0.82 Kg |
Abhishek Sharma (CEO)
Millennium Instruments Ltd.
Upsidc, F-12, Site-B, Industrial Area, Surajpur, Greater Noida
Greater Noida - 201306, Gautam Buddha Nagar, Uttar Pradesh, India